JD430

JD430

●CANopen communication
●STO (Safe Torque Off) make sure the safe running
●Strong anti-interference ability
●Isolation protection on communication port
●Main Supply Voltage : AC220V±15% 50~60Hz

  • Detaylar
ower Main supply voltage AC220V±15%  50~60Hz
Control circuit voltage DC18V~DC30V
Current Rated current(RMS) 10A
Peak current(PEAK) 27.5A
Brake chopper threshold DC380V±5V
Over-voltage alarming threshold DC400V±5V
Under-voltage alarming threshold DC200V±5V
Cooling method Cooling with fan
Size(width*hight*thicker) 220 x 195 x 66 mm
Operation
Environment
Operating temperature 0~40
Storage temperature -10~70
Humidity(non-condensing) 5~85%
Protection class IP20
Installation environment Installed in a dust-free,dry and lockable environment
Installation mode Vertical installation
Altitude Below 1000m
Atmospheric pressure 86kpa~106kpa
Genernal function Digital operation panel 4 buttons and 4 LED display
External I/O 8 digital input  12.5~30V.  7 digital output: OUT1, OUT2, OUT7 are 0.1A and OUT3 OUT6 are 0.5A . The input and outpput function can be defined freely.
Analog input 2 analog input, can be used to control speed and torque, the input rang is -10V~10V
Encoder signal output function Output encoder signal and master encoder signal are optional, can be used in the multiple axises synchronization application, the max. output frequency is 2MHz
Master singnal input function Can receive 3.3V~24V pluse/direction signal, CW/CCW signal. And the RS422 difference signal, the max. input frequency is 4MHz
Feedback signal Incremental A.B.Z.U.V.W.A/.B/.Z/.U/.V/.W/. Signal.
RS232 THe max. baudrate is 115.2 KHz, use JD-PC software to communicate with PC
RS485 THe max. baudrate is 115.2 KHz, use Modbus RTU protocol to communicate with control
CAN BUS THe max. baudrate is 1MHz,  use CANopen protocol to communicate with controller
STO function STO port can be connect to safe controller, switch, and sensor to protect the system